ИБП PS2200B
Дата последнего обновления: 15.05.2009
|
 |
цена: 0 тг.
Наличие на складе: есть
Последнее обновление информации:
15.05.2009 06:01
|
 |
Features
& Benefits
|
| |
|
- True sine wave output
- AVR to regulate fluctuate voltages
- As many as 8 outlets split into 3 separately
controlled groups
- Clear and informative UPS status LCD screen
- 1050 joules surge energy rating to prevent
damage from power surges and spikes
- Internet/LAN (RJ11/RJ45) surge protection
- Batteries are hot swappable and very easy to
replace
- Cold Start function. You can turn on UPS even
in case there is no AC line power
- Autorestart function can automatically turn
connected equipment back on after extensively long blackouts
- Free UPS management software included
|
|
| |
|
| |
 |
Specifications
|
|
|
|
Model
name
|
PS2200B
|
| Topology |
Line-Interactive
|
| On-battery
Output Waveform |
Sine
Wave
|
|
INPUT
|
|
Maximum
Capacity
|
2200VA
/1760W
|
|
Nominal
Input Voltage
|
100/110/120V
or 208/220/230/240V
|
|
Input
Frequency
|
50/60Hz Auto sensing
|
|
AC
Line-In Plug
|
100/110/120V
models
|
NEMA
L5-30P
|
|
|
208/220/230/240V
models
|
Depends
on local standards
|
|
OUTPUT
|
|
Nominal
Output Voltage
|
100/110/120Vac
or 208/220/230/240Vac
|
|
Output Voltage Regulation
|
Rated
Voltage +/- 5%
|
|
Transfer
Time
|
4 ms (typical)
|
|
Overload
Protection
|
Circuit
Breaker
|
|
Type
and Number of Outlets
|
100/110/120V
models
|
NEMA 5-15R 8 x Bttery Backup
|
|
|
208/220/230/240V
models
|
IEC 320 C13 8 x Bttery Backup
|
|
|
PROTECTION
|
|
Automatic
Voltage Regulation (AVR)
|
Yes
|
|
Data
Line Protection
|
RJ11
/ RJ45
|
|
Surge
Energy Rating
|
1050
Joules
|
|
Normal
Mode Noise Suppression
|
Full
time EMI/RFI filtering
|
|
USER
REPLACEABLE BATTERY
|
|
User Replaceable Battery
|
RBAT-18
|
|
Back-up
Time (Full load / Half load)
|
7
/ 26 min.
|
|
Typical
Recharge Time to 90%
|
<4 Hours
|
| DC Voltage |
48V
|
|
Front
Panel LEDs
|
AC
mode, Battery mode, Battery fault, Battery capacity,Buck Mode, Boost Mode,Load
percentage,Overload
|
|
Audible
Alarms
|
Battery mode, UPS fault, Overload
|
|
COMMUNICATIONS
INTERFACE
|
|
Communication
Port *
|
RS232
and /or USB Port
|
|
ENVIRONMENTAL
|
|
Operating
Temperature
|
0¢X~40¢XC
/ 32¢X~104¢XF
|
|
Storage
Temperature
|
-20¢X~60¢XC
/ -4¢X~140¢XF
|
|
Audible
Noise
|
<
40 dBA
|
|
PHYSICAL
|
|
Dimensions of main unit
(LxWxH):
|
Physical
|
17.5x6.7x8.5
inch / 445x170x215
mm
|
|
Packing
|
22x11.8x14.2 inch / 560x300x360 mm
|
|
Weight of main unit
|
Net
|
43.9
lb / 18.8 kg
|
|
Gross
|
48
lb
/ 21.1 kg
|
Dimensions of battery pack
(LxWxH): |
Physical |
17.5x6.7x8.5
inch / 445x170x215 mm
|
| Packing |
22x11.8x14.2
inch / 560x300x360 mm
|
| Weight of battery pack |
Net |
56.4
lb / 25.6 kg
|
| Gross |
60
lb / 27.2 kg
|
|
CONFORMANCE
|
|
Approvals
|
BSMI;
CE; GOST-R; UL/cUL; C-Tick; A-Tick
|
|
* USB
models have both RS232 and USB ports, but both ports cannot be used simultaneously.
For RS232 only model you can purchase RS232 to USB adapter.
Specifications are subject to change without notice .
|
Battery Pack Connection
Please plug Battery Power Cord into the External Battery Outlet as shown above,
and note:
1. If battery and UPS are at the same voltage range.
2. While connecting, please make sure if the color of the battery power cord
is the same with the
|